RING MAIN BUSBAR

        RING MAIN BUSBAR:



                                               fig.1.1

           Fig.1.1 shows the arrangement of ring bus bar system. The ends of the bus bars are returned to form a ring. In this system each feeder is supplied from two paths. By a dopting this scheme of connections, the alternators connected to any one of the bus bar section can be used for supplying the load to the feeders on any section.


ADVANTAGES :
                          1. Each feeder is supplied from two paths. 
                          2. The arrangement is quite economical

DISADVANTAGES :
                          1.  The opening of any section of the breaker may cause overloading of the circuits.
                          2. It is difficult to add any new cirouit to the ring
                                     mp3 tamil version

    TAMIL VIDEO VERSION :  https://youtu.be/dOpA37Ys6MU
ENGLISH VIDEO VERSION: https://youtu.be/Ktt8oaK0ivA


T     H      A      N        K             Y        O        U           B       Y    

                                          R      D      K
                                                   &
                             T            E             A             M

Comments

Popular posts from this blog

LAYOUT OF 110/11KV SUBSTATION

                   LAYOUT OF 110/11KV SUBSTATION: CIRCUIT DIAGRAM: THEORY : 1. The 3 phase 3 wire 110 KV feeder is tapped and brought to the Gang operated (GO) switch. The GO switch consists of isolators connected in each phase of the 3 phase line. 2. From the isolator the 110KV line is brought to the 110 KV Bus bar through Circuit Breaker (CB).  3. From the 110KV Bus bar, the 110 KV line is fed to the HT side of the 110KV/11KV stepdown transformer through Isolator. The transformer steps down the voltage to 11KV.  4. In fig.1.2. two 110/11KV transformers are connected from the 110 KV bus bar and the LT side of the power transformers are connected to the common 11KV Bus  through CB and Isolators. 5. From the 11KV Bus bar no of feeders are taken through  isolator and CB.  6. Lighting arresters are provided for protection from lightning and current transformers for...

SELECTION OF MOTORS FOR DIFFERENT DUTY CYCLES

   SELECTION OF MOTORS FOR DIFFERENT DUTY CYCLES : 1. Continuous duty cycle :                          It denotes the motor operation at a constant load torque to reach steady state temperature. The load time and. temperature time graph are shown in fig 1.1 EXAMPLES :               Paper mill drives compressors, conveyers, centrifugal pumps and fans                                              fig. 1.1 2. Short time duty :                   It denotes the operation of motor at constant load for short period followed by rest to cool down to the original starting temperature. Short time duty timings are generally 10, 30, 60 and 90 minutes. The load time and the temperature time graph are ...

FACTORS GOVERNING THE SELECTION OF MOTORS

                               FACTORS GOVERNING                                              THE                              SELECTION OF MOTORS :                 The following factors are taken into consideration while selecting a motor for industrial applications.  1. ELECTRICAL CHARACTERISTICS  a) Running.characteristics b) Starting characteristics c) Speed control  d) Braking  a) RUNNING CHARACTERISTICS :                                     The running characteristics of a motor include the speed-torque or the speed-current characteristic...